断裂力和连接牢固度测试仪 DL-D
English name:Breaking force and connection firmness tester
Model: DL-D
Product brand:远梓
适用方向:医用麻醉包的导管断裂力,导管和导管接头的连接牢固度,麻醉用针的针座与针管,衬芯与衬芯座的连接牢固度。
Application direction: the breaking force of the catheter of the medical anesthesia bag, the connection firmness of the catheter and the catheter joint, the connection firmness of the needle base and the needle tube of the anesthetic needle, and the connection firmness of the liner and the liner seat
仪器特点
采用7英寸K600+内核/点阵式65色 800*480分辨率触摸屏显示,PLC控制系统动态显示加载力值;操作界面可选:中文/英文/中英文切换;数字闭环控制,AD采集速度为500KHz,内码50万;高精度时钟芯片,断电存储;过载报警停机保护;触控操作:公称规格、测试、上行、下行、时间、标定。实时显示拉力. 并由机载打印机打印测试结果
Using 7-inch K600+ core/dot-matrix 65 color 800*480 resolution touch screen display, PLC control system dynamically displays the loading force value; Operation interface Optional: Chinese/English/English switch; Digital closed loop control, AD acquisition speed is 500KHz, internal code is 500000; High precision clock chip, power off storage; Overload alarm stop protection; Touch operation: nominal specification, test, up, down, time, calibration. The tension is displayed in real time. The test results are printed by the on-board printer
仪器参数
执行标准:GB15811-2016 、YY0321 中的有关断裂力和牢固度的试验方法而设计制造的。
测试项目:麻醉包的导管断裂力,导管和导管接头的连接牢固度,麻醉用针的针座与针管,衬芯与衬芯座的连接牢固度。
拉断力测试范围:0~80N,误差不大于±1%,分辨率0.01N。
时间设定:1-999S,误差不大于±0.5S。
断电保存:有
整机功率:70W
速度设定:50mm/min~500mm/min 误差不大于±5%。;
测力机构:内置
传感器:高精度力值传感器(有软硬件保护功能)
打印方式:每次可打印10次测试数据最大值与平均值和偏差值
发货清单:主机1台、合格证1份、配套夹具、操作说明书1份、打印纸1卷、配套砝码。
电源:AC90V-240V/50Hz
数据保存:机载针式打印机/可U盘导入电脑存储
净重:20kg 外形尺寸:400×240×240(mm)
服务:可定制非标仪器
仪器软件终身免费依国家标准规定升级服务、终身维护
Implementation standards: GB15811-2016, YY0321 in the test method of fracture force and firmness designed and manufactured.
Test items: the catheter breaking force of the anesthesia kit, the connection firmness of the catheter and the catheter joint, the needle base and the needle tube of the anesthesia needle, and the connection firmness of the liner and the liner seat.
Tensile force test range: 0 ~ 80N, error is not more than ±1%, resolution 0.01N.
Time setting: 1-999S, error is not more than ±0.5S.
Power off save: Yes
Power: 70W
Speed setting: 50mm/min~500mm/min error is not more than ±5%. ;
Force measuring mechanism: built-in
Sensor: High-precision force value sensor (with hardware and software protection function)
Printing method: Each time can print 10 test data maximum and average value and deviation value
Delivery list: 1 set of main machine, 1 certificate, 1 fixture, 1 operation manual, 1 roll of printing paper, supporting weights.
Power supply: AC90V-240V/50Hz
Data storage: on-board needle printer/U disk can be imported into the computer storage
Net weight: 20kg Dimensions: 400×240×240 (mm)
Services: Customizable non-standard instruments
Instrument software life-long free upgrade service and lifelong maintenance in accordance with national standards
售后服务
整机质保壹年
上门培训维修
七天质量问题全款退换货服务
仪器软件终身免费依国家标准规定升级服务、终身维护
The whole machine quality guarantee one year
door-to-door training maintenance
seven days quality problem full-money return service
instrument software life-long free according to the national standard upgrade service, life-long maintenance